33. Absorption area: The total absorption area of seepage pits that serve an isolated dwelling must comply with the minimum standards in the following table, according to the number of bedrooms:
___________________________________________________
Number of Minimum total absorption area
bedrooms (square metres)
___________________________________________________
1 15
___________________________________________________
2 20
___________________________________________________
3 30
___________________________________________________
The total absorption area of seepage pits that serve another building must comply with the minimum standards in the following table, according to the total daily flow:
___________________________________________________
Total daily Minimum total absorption area
flow (litres) (square metres)
___________________________________________________
0 to 540 15
___________________________________________________
541 to 1080 20
___________________________________________________
1081 to 1620 30
___________________________________________________